Druckwägezelle
TC-FR(T)-G TEDS RohS
Compact and lightweight makes it easy to install on existing equipment. In addition, since it is made of stainless steel (SUS630), it can be widely applied as a detector for devices requiring corrosion resistance
Besonderheiten
Compact, lightweight, corrosion-resistant, low-cost
Technische Daten
Model | Unit | Rated Capacity (R.C.) | ||||||||||||
TC-FR(T)-G | N | 0.5 | 1 | 1.5 | 2 | 3 | 5 | 10 | 20 | 50 | 100 | 200 | 500 | |
kN | 1 | 2 | 3 | 5 | 10 | 20 | 30 | 50 | 100 | 200 | 300 | 500 | 1000 |
Rated Capacity (R.C.) | Resonance Frequency | Weight (Approx.) | |
500 N | 51 kgf | 3.6 kHz | 230 g |
1 kN | 102 kgf | 5.0 kHz | 230 g |
2 kN | 204 kgf | 6.0 kHz | 230 g |
5 kN | 510 kgf | 7.0 kHz | 230 g |
10 kN | 1.02 tf | 10.0 kHz | 230 g |
20 kN | 2.04 tf | – | 230 g |
Model | TC-FR(T)-G |
Safe Overload | 150 % R.C. |
Rated Output (R.O.) | 2 mV/V ±1 % |
Non-Linearity | 0.15 % R.O. |
Hysteresis | 0.1 % R.O. |
Non-Repeatability | 0.05 % R.O. |
Excitation Voltage | 15 V |
Input Resistance | 425 Ω ±50 Ω |
Output Resistance | 350 Ω ±5 Ω |
Insulation Resistance | >1000 MΩ |
Compensated Temperature Range | –10 °C to 70 °C |
Safe Temperature Range | –10 °C to 70 °C |
Temperature Effect on the Zero Signal | 0.05 % R.O. / 10 °C |
Temperature Effect on the Output | 0.1 % R.C. / 10 °C |
Cable | Ø 6 mm shielded 6-conductor wire, 5 m direct connection |
Material | Stainless steel |
TEDS | Built-in |
Environmental Regulations | RoHS/REACH |