Druckwägezelle

TC-KR(T)-G TEDS RohS

The structure is extremely simple, so it is easy to handle and maintain. It can be widely applied to bolt tension, press forming equipment and so on.

Besonderheiten

Compact · Center hole type · Suitable for press fitting, caulking

Technische Daten

Model Unit Rated Capacity (R.C.)
TC-KR(T)-G N 0.5 1 1.5 2 3 5 10 20 50 100 200 500  
kN 1 2 3 5 10 20 30 50 100 200 300 500 1000
Rated Capacity (R.C.) Resonance Frequency Weight (Approx.)
5 kN 510 kgf 13.2 kHz 0.3 kg
10 kN 1.02 tf 8.2 kHz 0.95 kg
20 kN 2.04 tf 10.9 kHz 1.0 kg
30 kN 3.06 tf 8.0 kHz 1.0 kg
50 kN 5.1 tf 13.5 kHz 1.0 kg
100 kN 10.2 tf 19.0 kHz 1.3 kg
200 kN 20.4 tf 10.0 kHz 2.9 kg
300 kN 30.6 tf
Model TC-KR(T)-G
Safe Overload 120 % R.C.
Rated Output (R.O.) 1 mV/V ±1 %
Non-Linearity 0.5 % R.O.
Hysteresis 0.5 % R.O.
Non-Repeatability 0.1 % R.O.
Excitation Voltage 18 V
Input Resistance 700 Ω ±7 Ω / 350 Ω ±3.5 Ω (5 kN only)
Output Resistance 700 Ω ±7 Ω / 350 Ω ±3.5 Ω(5 kN only)
Insulation Resistance >2000 MΩ (DC 50 V)
Compensated Temperature Range –10 °C to 70 °C
Safe Temperature Range –20 °C to 100 °C
Temperature Effect on the Zero Signal 0.1 % R.O. / 10 °C
Temperature Effect on the Output 0.1 % R.C. / 10 °C
Cable Ø 6 mm shielded 6-conductor wire, 3 m direct connection
Material Nickel chrome molybdenum steel
TEDS Built-in
Environmental Regulations RoHS/REACH

Umrissmaße