Druckwägezelle
TC-LPR(T)-G TEDS RohS
Load Button Removable thin load cell
Besonderheiten
It is thin and supports RoHS, and TEDS incorporation, a road button are removable
Technische Daten
| Model | Unit | Rated Capacity (R.C.) | ||||||||||||
| TC-LPR(T)-G | N | 0.5 | 1 | 1.5 | 2 | 3 | 5 | 10 | 20 | 50 | 100 | 200 | 500 | |
| kN | 1 | 2 | 3 | 5 | 10 | 20 | 30 | 50 | 100 | 200 | 300 | 500 | 1000 | |
| Rated Capacity (R.C.) | Resonance Frequency | Weight (Approx.) | |
| 500 N | 51.0 kgf | 2.5 kHz | 250 g |
| 1 kN | 102 kgf | 3.8 kHz | 250 g |
| 3 kN | 306 kgf | 7.3 kHz | 250 g |
| 5 kN | 510 kgf | Please contact us | |
| 10 kN | 1.02 tf | Please contact us | |
| Model | TC-LPR(T)-G |
| Safe Overload | 120 % R.C.(500 N – 3 kN) 150 % R.C. (5 kN, 10 kN) |
| Rated Output (R.O.) | 1 mV/V ±10 % |
| Non-Linearity | 0.1 % R.O. (500 N – 3 kN) 0.3 % R.O.(5 kN, 10 kN) |
| Hysteresis | 0.1 % R.O. (500 N – 3 kN) 0.3 % R.O. (5 kN, 10 kN) |
| Non-Repeatability | 0.05 % R.O. |
| Excitation Voltage | 15 V (500 N – 3 kN) 12 V (5 kN, 10 kN) |
| Input Resistance | 382 Ω ±10 Ω |
| Output Resistance | 350 Ω ±3.5 Ω |
| Insulation Resistance | >1000 MΩ(50V DC) |
| Compensated Temperature Range | –10 °C to 70 °C |
| Safe Temperature Range | –30 °C to 80 °C |
| Temperature Effect on the Zero Signal | 0.1 % R.O. / 10 °C |
| Temperature Effect on the Output | 0.1 % R.C. / 10 °C |
| Cable | Ø 6 mm shielded 6-conductor wire, 5 m direct connection |
| Accessory | Load button |
| TEDS | Built-in |
| Environmental Regulations | RoHS/REACH |
Umrissmaße