Druckwägezelle

TC-WLD(T) TEDS

TEAC TC-WLD(T)

Load cell for spot welding pressure control.

Besonderheiten

Compact, lightweight

Anwendungen

  • Ideal for measuring pressurizing force between electrodes for resistance welding machines,
    such as in spot welding of factory automation and automobile production lines.
  • By simultaneous use with portable digital indicator TEAC TD-01 Portable, on-site pressurization management can be done easily.

Technische Daten

Model Unit Rated Capacity (R.C.)
TC-WLD(T) N 5 10 20 50 100 200 500          
kN 1 2 3 5 10 20 40 50 100 200 500 1000
Model TC-WLD(T)
Rated Capacity (R.C.) 10 kN, 20 kN
Safe Overload Rating 120 % R.C.
Rated Output (R.O.) 1 mV/V ±50 % (10 kN)
1.5 mV/V ±50 % (20 kN)
Non-linearity 1. 0 % R.O. (10 kN)
2.0 % R.O. (20 kN)
Hysteresis 1 % R.O.
Repeatability 1 % R.O.
Zero Balance ±10 % R.O.
Safe Excitation Voltage 7 V
Input Terminal Resistance 350 Ω ±5 %
Output Terminal Resistance 350 Ω ±5 %
Insulation Resistance >1000 MΩ (DC 50 V)
Compensated Temperature Range 0–50 °C
Permissible Temperature Range –10 °C to 60 °C
Temperature Effect on Zero Balance 0.5 % R.O. / 10 °C
Temperature Effect on Output 0.5 % R.C. / 10 °C
TEDS Built-in
NDIS Standard Receptacle NDIS7P (PRC03-21A10-7F)
Supplied cable ⌀ 6 mm shielded 6-conductor wire (1 m) with plug connector at both ends
Connector: PRC03-12A10-7M

*The specifications and appearance are subject to change without notice for improvement.

Umrissmaße

TEAC TC-WLD(T) Outline Dimensions