Druckwägezelle

TC-WLD(T) TEDS

TEAC TC-WLD(T)
TC-WLD(T): Gebrauchsfertige Druckwägezelle für die Kraftmessung an Punktschweißmaschinen (z.B. in Verbindung mit dem tragbaren Anzeigegerät TD-01)

The TC-WLD(T) is a ready-to-use strain-gauge load cell dedicated for pressure force measurement on spot welding machines in industrial production lines. It consists of a handy all-metal housing with a spring-loaded handle to ensure safe operation. A 6-core shielded cable with two robust PRC connectors and a length of one meter is included as standard to allow quick and safe connection with the TEAC TD-01 Portable indicator, for example.

The TC-WLD(T) is available for forces up to 10 kN or 20 kN and has a safe overload handling of 120 percent. Linearity is as high as one percent (10 kN) or two percent (20 kN) and the compensated temperature range from zero to 50 degrees celsius guarantees exact measurement results even under adverse environmental conditions.

The built-in Transducer Electronic Data Sheet (TEDS, IEEE 1451.4) allows auto-identification and auto-calibration of the load cell to ensure time-saving setup and avoid scaling and calibration errors.

Besonderheiten

Compact, lightweight, ready to use with TD-01 Portable indicator/recorder

Anwendungen

  • Ideal for measuring pressure force between electrodes of resistance welding machines,
    such as in spot welding of factory automation and automobile production lines.
  • In combination with the digital TEAC TD-01 Portable indicator, on-site pressure calibration or control can be accomplished safely and easily.

Technische Daten

Model Unit Rated Capacity (R.C.)
TC-WLD(T) N 5 10 20 50 100 200 500          
kN 1 2 3 5 10 20 40 50 100 200 500 1000
Model TC-WLD(T)
Rated Capacity (R.C.) 10 kN, 20 kN
Safe Overload Rating 120 % R.C.
Rated Output (R.O.) 1 mV/V ±50 % (10 kN)
1.5 mV/V ±50 % (20 kN)
Non-linearity 1. 0 % R.O. (10 kN)
2.0 % R.O. (20 kN)
Hysteresis 1 % R.O.
Repeatability 1 % R.O.
Zero Balance ±10 % R.O.
Safe Excitation Voltage 7 V
Input Terminal Resistance 350 Ω ±5 %
Output Terminal Resistance 350 Ω ±5 %
Insulation Resistance >1000 MΩ (DC 50 V)
Compensated Temperature Range 0–50 °C
Permissible Temperature Range –10 °C to 60 °C
Temperature Effect on Zero Balance 0.5 % R.O. / 10 °C
Temperature Effect on Output 0.5 % R.C. / 10 °C
TEDS Built-in
NDIS Standard Receptacle NDIS7P (PRC03-21A10-7F)
Supplied cable Ø 6 mm shielded 6-conductor wire (1 m) with plug connector at both ends
Connector: PRC03-12A10-7M

*The specifications and appearance are subject to change without notice for improvement.

Umrissmaße