| Power supply |
DC 24V (±10%) 13 W, AC 100–240 V (AC adapter is optional) |
| Environment |
Temperature |
0–40 °C (operation) –20 °C to 60 °C (storage) |
| Humidity |
85% RH or less (without condensation) |
| Dimensions, Weight |
Approx. 114 mm × 96 mm x 140 mm (without protrusions), About 960 g |
| Applicable standards |
EMC |
FCC (class A, to be scheduled) |
| Safety |
CE, UL (to be scheduled) |
| Display |
4.3/inch LCD color resistive touch panel |
| Display range |
–32,000 to +32,000 |
| Display Language |
English / Japanese / Chinese* / Korean* |
| Screen |
Digital Load Value, Waveform, Archive Data, Settings |
| Waveform |
X-axis Time |
80 ms, 170 ms, 400ms, 800ms, 2 s, 4 s, 10 s, 30 s, 60 s, 120 s |
| Displacement |
2000, 4000, 6000, 8000, 10000, 15000, 20000, 30000 |
| Y-axis |
Load (STD) / Load and displacement (biaxially) |
| Comparison waveform |
Band judgment |
Offset reference band / Designated value band |
| Multi-zone judgment |
Up to 5 judgment zones can be set by device or external signal |
| Comparison judgment |
Load: HH / HI / OK / LO / LL Displacement: HI / OK / LO |
| Hold setting |
Constant comparison, sampling, peak, bottom, peak to peak, maximum/minimum, inflection point and
average value |
| Audible Beep |
Sounding when judgments are not OK (switchable on/off) |
| Measurement work settings |
Number of works |
16 (work can be copied) |
| Switching |
External input signal / manual |
| Data recording |
Built-in memory (up to 70) or SD cards |
| D/A converter |
Output range |
Isolated, current: 4–20 mA, voltage: –10 V to +10 V) |
| Conversion rate |
Same as A/D converting rate |
| Resolution |
current output: about 1/43000, voltage output: about 1/59000 (when set to ±10 V) |
| Impedance |
350 Ω or less (current output) / 2 kΩ or more (voltage output) |
| Communication interface |
RS-232C (D-sub 9-pin), USB |
| Control input/output signal (photocoupler insulation) |
Input signal |
Differential pulse displacement sensor (A phase, B phase), backlight On/Off, touchpanel lock,
reset, work select, hold zone select, clear, judgment on/off, measurement start/end, preset
displacement, digital zero |
| *Signals are input when shorted/opened (contact or non-contact (transistor, TTL open collector))
between any input terminal and the COM terminal. |
| Output signal |
Load judgement (HH/HI/OK/LO/LL), displacement judgment (HI/OK/LO), load cell abnormal,
measurement completed, trigger (1, 2) |
| *NPN open collector (sync type) |
| *Maximum current: 20 mA, voltage: 30 V |
| Check functions |
Load cell check (static strain/nterruption detection), contact terminal check |
| Date and time setting |
Date (YYYY/MM/DD) and time can be set |
| Recording media |
SD/SDHC card (2–32 GB, Class 10 recommended) |