Tension/Compression Load Cell

TU-GR-G RohS

Features

Shear · Center hole type

Specifications

Model Unit Rated Capacity (R.C.)
TU-GR-G N 0.5 1 1.5 2 3 5 10 20 50 100 200 500  
kN 1 2 3 5 10 20 30 50 100 200 300 500 1000
Rated Capacity (R.C.) Resonance Frequency Weight (Approx.)
5 kN 510 kgf 3.5 kHz 2.2 kg
10 kN 1.02 tf 5 kHz 2.2 kg
20 kN 2.04 tf 7.6 kHz 2.2 kg
50 kN 5.1 tf 8.8 kHz 3.7 kg
100 kN 10.2 tf 7 kHz 8.5 kg
200 kN 20.4 tf 5.6 kHz 20 kg
500 kN 51 tf 5.9 kHz 54 kg
1000 kN 102 tf 3.3 kHz 140 kg
Model TU-GR-G
Safe Overload 150%R.C.
Rated Output (R.O.) 2 mV/V ±1 %
Non-Linearity 0.05 % R.O. (5–200 kN)
0.15 % R.O. (500–1000 kN)
Hysteresis 0.1 % R.O. (5–200 kN)
0.15 % R.O. (500–1000 kN)
Non-Repeatability 0.03 % R.O. (5–200 kN)
0.1 % R.O. (500–1000 kN)
Excitation Voltage 20 V
Input Resistance 350 Ω ±3.5 Ω
Output Resistance 350 Ω ±3.5 Ω
Insulation Resistance >1000 MΩ (DC 50 V)
Compensated Temperature Range –10 °C to 60 °C
Safe Temperature Range –30 °C to 80 °C
Temperature Effect on the Zero Signal 0.05 % R.O. / 10 °C
Temperature Effect on the Output 0.1 % R.C. / 10 °C
Cable Ø 8 mm shielded 4-conductor wire, 5 cm direct connection
Material Alloy tool steel
Accessories Eye bolt

Outline Dimensions